Air Heaters

The ISE type electric heaters comprise a range of Ex e air duct heaters, custom built to meet client specification and suitable for use in Zone 1 or Zone 2 hazardous areas.

FEATURES AND BENEFITS
  • Certified to ATEX or IECEx standards
  • A range of Ex e Gas Group IIC, increased safety certified duct air heaters
  • Temperature classifications T2 to T6
  • Elements are certified Ex e for use in Zone 1 hazardous areas
  • Elements are individually replaceable on site without the need for special tools
  • Terminal box is certified weatherproof to IP66 and IP67
  • Anti-condensation heater fitted if required
  • Various types of over-temperature cut-outs available, e.g. thermostats, RTD’s or thermocouples
  • Air handling units
  • Drying ovens
  • Furnace heating
  • HVAC duct heating
  • Space heating

Certifications

  • ATEX / IECEx EX logo II 2 G
    Ex e IIC T1 to T6 Gb IP67
  • CU TR (EAC), CCOE, CNEx, Inmetro

Heating Elements

  • Manufactured from 80/20 NiCr resistance wire with high purity compacted magnesium oxide powder sheathed with corrosion/erosion resistant tube (eg: Incoloy 800/825, 316/316L stainless steel, Inconel 600/625, 321 stainless steel, Titanium)

Supports on the heating elements

  • Elements are supported in a baffle assembly to prevent flow-induced vibration

Installation of the heating elements

  • Elements are sealed into the mounting flange by either brass or stainless steel bushings to facilitate individual replacement of elements

Temperature Monitoring

Generally over temperature protective devices are installed as follows:

Where elements are NOT in a hazardous area:

  • 1 thermostat per heating stage, sensing element surface temperature
  • 1 thermostat sensing air temperature

Where elements ARE in a Hazardous Area:

  • 3 thermal cut-outs (1 per phase), per heating stage sensing element surface temperature
  • 1 thermal cut-out sensing air temperature

Note: The air temperature sensor is not required if the terminal box is thermally spaced from the duct

Terminal Box

  • Lightweight construction, manufactured from either carbon steel (corrosion protected) or 316L stainless steel throughout

Testing

Duct Construction

  • Manufactured from either stainless steel or pre-galvanised sheet steel to suit the specific working environment; the element-mounted flange is designed to enable removal of the heater bundle without disturbing the remaining ductwork
  • Elektrisch
  • Heißwasser aus Ringleitung
  • Dampf
  • Öl-Ringleitung
  • Kombinationsbeheizung aus Strom, Wasser, Dampf und / oder Öl

Voltage

  • Suitable for voltages up to 690V

Special Features

  • Where a hazardous gas is present within the duct, the elements are supplied certified Ex e for use in an ATEX / IECEx Zone 1 Area
Scroll to Top