Hot Oil Systems
SEICO designs heat transfer oil circulation systems that use pumps with magnetic coupling or canned motor circulation pumps to convey thermal oil flow through a closed circuit of up to 400°C / 752°F. Heating is applied by utilizing electrical heating inserts, with heating capacities of up to 20 MW. The systems are plug-and-play units. Depending on your requirements, the units can be equipped with heat exchangers for heating and/or cooling. SEICO’s engineering department is specialized in designing customized units in accordance with customers’ specification – under careful consideration of hazardous area standards – and are harmonized with specific national and local rules.
Further customers’ primary heating sources like steam or hot-water-ring mains are alternatively possible by using SEICO annular-gap heat exchangers.
For “smaller” standardized mobile hot-oil heating / cooling units, please ask for SEICO MHO-type systems (with 15 kW to 60 kW heating capacity, up to 350°C / 662°F operating temperature).
Get a Quote- High adaptability: Heat transfer oil circulation systems are available in a variety of sizes (standard: 15 kW up to 20 MW) with the same quality level due to its modular design
- Great ecology: The electric Multi-Annular-Ring Split (MRS) heater allows maximum electric efficiency without CO₂ emissions
- Hot-Oil heating systems operate with low pressures and are easily operable above 200°C / 392°F compared to hot-water systems
- Worldwide commissioning support and service is provided
- Agitator
- Calendering
- Coating equipment
- Dryer heating
- Extruders
- Film production
- Laminating
- Reactors
- Tank storage heating
- Winders
- Presses
Certifications
- AD2000 HP0
- ASME Code
- CML (AQSIQ, SQL)
- GOST-R, KOSHA, U-GOST
- DIN 4754
- DIN EN ISO 9001
- DIN EN ISO 3834
- DIN EN 13445
- Explosion Protection Directive 2014/34/EU, ATEX, NEPSI, CCC, IEC-EX
- Machinery Directive 2006/42/EC
- Pressure Equipment Directive 2014/68/EU
Further customized certifications can be provided to meet your requirements
Testing
- Dye penetrant
- Electric
- Pressure and strength tests
- Tightness tests
- X-ray inspection
Further customized testing can be provided to meet your requirements